SFI-DL-FW-Series
Product
SFI-DL-FW-Series

Design
- Window : Double window
- Construction: Full Window (Window size = Line Size)
- Flow Pattern: In-line
- Indication: Flappers, Kite, Rotating Wheel
- Design Standards: Body - ASME Sec VIII
- Thermal Insulation: Mica shield can be provided for high temperature use.
- Sub Zero Application: Frosting shield can be provided.
- Size: 15 NB to 300nb (1/2' to 12')
- End Connection: Flanged / Screwed
- Rating: Up to 300 lbs.
Material Data
| Component | Material |
|---|---|
| Body | ASTM A 216WCB / LCB , CF8,CF8M,CF3,CF3M,ASTM A890/A890M Grade 5A,ASTM A890/A890M Grade 4A,SS 304/304L,SS316/316L |
| Cover Plate | SA 105 , SA 516GR 60/70, SS 316, SS304, DUPLEX, SUPER DUPLEX |
| Fastners | A193 B7/ 2H , SS 316, SS304, ASTM A193 Grade B8,ASTM A193 Grade B8M, IS 1367 |
| Glass | Toughened Borosilicate, Moulded silicate |
| Gaskets | EPDM, Neoperene, Sprial wound SS 304/316 |
| Indicators | SS 304/304 l , SS 316/316l, Duplex , Super Duplex, Monel |

Dimensions
| Size | FF-mm | B-mm |
|---|---|---|
| 40nb | 175 | 40 |
| 50nb | 195 | 50 |
| 80nb | 245 | 80 |
| 100nb | 285 | 100 |
| 150nb | 390 | 150 |
| 200nb | 450 | 200 |