BCP-Series

Product

BCP-Series

BCP-Series Strainers

Design

  • Standard sizes from ½” – 1½” – screwed, 2”–8” – Flanged
  • Available In Screwed and Flanged ANSI B16.5 150 LBS SORF Only
  • Standard thru bolt cover design with ANSI B16.5 15O # Rating
  • Perforated screens are standard
  • May be installed in horizontal pipelines
  • Castings can be radiographed on request
  • Drain/Vent with plug is standard. Drain/Vent valves can be supplied on request
  • Large body with Guaranteed low pressure drop as per Tab 3
  • Net free straining area minimum 6 times of pipe c/s area for standard screen
  • Hinged Covers on request
  • Drain/Vent valve on request
  • Dp Indicators/ DP switch on request
  • Mesh Lined Screens on request
  • Pressure rating 15 bar

Material Data

ComponentMaterial
BodyASTM A216 WCB, CF8, CF8M,Ni Al Bronnze, Cast Iron
CoverA105, SA 516 GR 70, CS TO IS 2062, SS316,304
FastnersA193 B7 Bolts & A 194 2 H Nuts with spring washer SS 304/316
GasketsCAF, NACF, Neoprene, NItrile,PTFE, Spiral wound gaskets
Drain / Vent PlugA105, CS TO IS 1875-II, Stainless Steel
Filter ElementSS 304,316, Duplex, Brass, Monel, Hastalloy C

Standard Screens

Size RangeOpening
15mm-25mm2mm
40mm-80mm2mm
100mm-200mm3mm

BCP-Series Engineering Diagram Blueprint

Dimensions

SizeABCDEFG
mmmmmmmmmmmmmmmm
4038241121254165111343
5051267133295194124397
8076333167386270152502
100102438213400273187527
150152498222629467298791
2002036863308796863521073