ASC IHB P Series

Product

ASC IHB P Series

A Series Strainer

Design

  • Horizontally mounted design
  • Self cleaning by using backflush principle created by reverse flow
  • Standard sizes from 2” – 24”. Larger sizes available upon request.
  • Available In flanged end connections.
  • Standard thru bolt cover design. Other covers on request
  • Perforated screens are standard.
  • All welders are qualified to ASME Section IX.
  • Strainers designed to meet the requirements of ASME Section VIII,Div.1.
  • Drain with plug is is standard . Drain valves can be supplied on request
  • Vents with plug and Dp indicators are standard
  • Large body with Guaranteed low pressure drop as per Table 3in engineering data.
  • Net free straining area minimum 6 times for standard screen
  • DP Switch are standard. Transmitters can be supplied on request
  • Electrically actuated butterfly backflush valve are standard. Other valves and Pneumatic valves on request
  • Robust bearing design
  • Backflush primemover -3 Phase AC motor 230 volts standard for sizes higher that 25 nb single phase AC motor 230v standard for 25b and lower.
  • Gear box to reduce sppeds to 7 to 14 rpm

Material Data

ComponentMaterial
BodyIS1239,3589 ASTM A106, SS304/316, DUPLEX STEEL
CoverA105, SA 516 GR 70, CS TO IS 2062, SS316,304, DUPLEX STEEL
FastnersA193 B7 Bolts & A 194 2 H Nuts with spring washer. SS 304/316
GasketsCAF, NACF, Neoprene, NItrile,PTFE
Drain / Vent PlugA105, CS TO IS 1875-II, Stainless Steel
Filter ElementSS 304,316, Duplex, Brass, Monel, Hastalloy C

Standard Screens

Size RangeOpening
2"-8" ( 50mm-200mm)0.125 IN. (3.2mm)
10"-12" (250mm-300mm)0.125 IN. (3.2mm)
14"-24" (250mm-600mm) 0.188 in. (4.8mm)

ASC IHB P Series Engineering Diagram Blueprint

Control Panel Specs

IP 65 Double door panel is standardData Capture
Panel Size : 400 x 400 x300mmCleaning cycle – Period run
Power supply : 230 Volts 3 phase ACValve failure report
3 modes viz., Manual, Built in auto and Remote -with 3 point selector swith as standardOlr activated report
Adjustable field setable, Periodic and cyclic timerDebris overload through Dp switch report
Valve Feed Back-Open, close and errorIndications
Overload protection for Backflush Motor is standardPower On
RS 485 output for remote data CollectionFilteration ON
LCD DisplayFilter choked
Drain Valve open

Dimensions

Size
in-mm
A
mm
B
mm
C
mm
D
mm
2" - 50375110365300
3" - 80535145370300
4" - 100579175400300
6" - 1501141215450300
8" - 2001313250500300
10" - 2501507285675300
12" - 3001766315750300
14" - 3501538375900300
16" - 40019924001000300
20" - 50020914351125300
24" - 60034445001250300